What was found
INSPECTION TYPE: C, SUSPECT CRACK ON LT HORIZONTAL STAB UPPER FRAME JUST I/B OF ELEVATOR RIB STA 173.21. REPAIR CARRIED OUT IAW SMRO EO 2003-001-004 UPS ENGINEERING FILE 727-55-20029.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, SUSPECT CRACK ON LT HORIZONTAL STAB UPPER FRAME JUST I/B OF ELEVATOR RIB STA 173.21. REPAIR CARRIED OUT IAW SMRO EO 2003-001-004 UPS ENGINEERING FILE 727-55-20029.