What was found
INSPECTION TYPE: C, COMPLY WITH MPI P 14035: IAW M REPAIR TO AIRSTART DOOR CUTOUT AT 100Y CYCLES OR 3 MONTHS WHICHEVER COMES FIRST IAW EO DC8-5330-0793, STATION 25 TO 55 LONG. 28L-30L AT DOOR CUTOUT REMOVED EXISTING FILLERS,NDT VERIFIED NO CRACKS AT EXISTING CUTOUTS, FABRICATED AND INSTALLED DOUBLER AND FILLERS IAW DC8-5330-0795, SRO 8530020,AND SRM. 53-2-0 FIG. 13