What was found
INSPECTION TYPE: C, 8 PREVIOUS BLENDOUTS BELOW C-PIT DOOR BETWEEN LONG. 34R TO 30R FROM STA. 1220 TO 1260 CUT AND REMOVED SKIN SECTION FROM STATION 1190-1230 BETWEEN LONG 29R TO 34R,NDT VERIFIED NO CRACKS AT CUTOUT, FABRICATED AND INSTALLED SKIN SECTION AND SPLICE DOUBLERS IAW DC8-5330-18928-A AND SAA SK 807-033.