What was found
INSPECTION TYPE:C3 STA. 1260-1280 LONG. 36 IS CRACKED, CUTOUT DAMAGED SECTION,FABRICATED AND INSTALLED LONGERON SECTION, STRAPS,CHANNELS AND DOUBLERS IAW UPS ENGINEERING FILE NUMBER DC8-53-20339 DATED 07/13/03,AND SAA SK 807-542 REV. IR DATED 06/27/03