What was found
INSPECTION TYPE:C2 STRUCTURE INSIDE FWD ENTRY DOOR SNUBBER POCKET CRACKED, STA 15 LONG 16L. REMOVED DAMAGED INTERCOSTALS, FABRICATED REPAIR DOUBLER, FILLERS AND INSTALLED IAW SRM 53-2-0 FIG 2, AT FWD ENTRY DOOR SNUBBER POCKET STA 15, LONG 16L.