What was found
NOSE GEAR GREEN DN LGT FAILED TO ILUM W/GEAR HANDLE DN. EICAS MSG GEAR DISAGREE & GEAR DOORS DISPLAYED. DOORS & GEAR AMBER LGTS ILLUM. INDIC ATIONS WERE NORM AFTER ALTN GEAR EXT. REF LP 195912 R & R NLG RETRACT ACTUATOR PER MM VALVE & NOSE GEAR LOCK ACTUATOR PER MM 32-34-01. REMOVED NLG OPERATED SEQUENCE VALVE. INSTALLED NEW NOSE GEAR OPERATED SEQUENCE VALVE PER MM32-34-06 PERFORMED SUCCESSFUL N/G EXTEN AND RETRACT TEST. JACKED A/C, FOUND NO HYD LEAKS PER MM 7-1-02 MM32-34-00 PG 501-504