What was found
F/S 960 LBL 60 FLOORBEAM AT LIGHTING HOLE ON VERT FLANGE AT CENTER OF HOLE HAS A 5" CRACK GOING AT HORIZ ANGLE. STOP DRILLED CRACKED FLOORBEAM, FABRICATED AND INSTALLED 2. REPAIR ANGLES IAW SAA SK 807-858978 AND UPS EODC8-53-20486.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
F/S 960 LBL 60 FLOORBEAM AT LIGHTING HOLE ON VERT FLANGE AT CENTER OF HOLE HAS A 5" CRACK GOING AT HORIZ ANGLE. STOP DRILLED CRACKED FLOORBEAM, FABRICATED AND INSTALLED 2. REPAIR ANGLES IAW SAA SK 807-858978 AND UPS EODC8-53-20486.