What was found
AFT CARGO COMPT, LT STA1500 IN BETWEEN LBL30 AND LBL45 FLOORBEAM UPPER CHORD FOUND CORROSION. CORROSION BLEND OUT 0.024" BY 1" BY 6". FLOORBEAM UPPER CHORD AT STA 1500 LBL 28 TO MOST O/B REPAIRED AS PER SRM 51-40-04 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPT, LT STA1500 IN BETWEEN LBL30 AND LBL45 FLOORBEAM UPPER CHORD FOUND CORROSION. CORROSION BLEND OUT 0.024" BY 1" BY 6". FLOORBEAM UPPER CHORD AT STA 1500 LBL 28 TO MOST O/B REPAIRED AS PER SRM 51-40-04 FIG 2.