What was found
INSPECTION TYPE:C M/D RIGHT BS 860 FRAME TENSION TIE ATTACHMENT AREA FOUND 1EA HOLE CRACK AT TENSION TIE FWD CHANNEL AND 1EA HOLE CRACK AT TENSION TIE AFT CHANNEL CRACK LENGTH 0.030 INCH. M/D RIGHT BS 860 TENSION TIE FWD AND AFT CHANNEL REPAIRED AT RIGHT VERTICAL POST TO RIGHT MOST O/B AREA AS PER RS R53-25-35522 SHEET 1 ITEM 1 PERFORM SUPPLEMENTAL INSPECTIONS AS PER RS R53-25-35522 REF F AND UPS EO B747-5310-23739-A CONTINUE INSP IS REQUIRED.