As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C RT WING, INBD LUG BORE OUT OF LIMIT. FAB BUSHING ON TRAVELER T6/621746 AND INSTALLED IAW EA 757-5720-27-A1 511 STEP NR 5 ON EA 757-5720-27-A1511 AFTER REWORK LUG DIAMETER IS 1.7 903 STEP NR 6 ON EA 757-5720-27-A1511 MATERIAL THICKNESS BEWTEEN EDGE OF LUG HOLE AND OUTSIDE EDGE IS 1.663.