As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C DENT IN AFT CARGO FUSELAGE FRAME STA 1340, S26L DIMENSIONS OF THE DENT, 1.3'L BY 1.0'W BY 0.030' D REMOVE TRANSITIONAL PANEL LT STA 1310-1410 IAW SRM 51-40-02 TRIM OUT DENT AREA IAW EA 75 7-5362-27-A1561 STEP 1 PREM. TRIM OUT SIZE: 1.3' L BY 1.3' W ACCOMPLISHED FINAL E.A. 757-5362-27-A1561 AND OPS E.O. NR B757-5310-25465-A WITH NO DE DEVIATIONS.