What was found
INSPECTION TYPE:C3 ELONGATED FASTENER HOLE AT AFT LWR CORNER OF R1 DOOR FS 190 JUST ABOVE L21R. REMOVED DAMAGED WEB AT STA 190 L21R IAW SRM 51-01-21, FABRICATED AND INSTALLED WEB AT STA 190 L21R IAW DWG 5615700 ITEM 17 AND SRM 51-01-08, SRM 51-1-8 AND SRM 51-1-20D.