What was found
INSPECTION TYPE:N/A RIGHT WING INBOARD SLAT HAS A 16 INCH CRACK ON THE INBOARD END. A/C FERRIED TO SDF FOR REPAIR. REMOVED RT INBD SLAT PER MM 27-80-20-4. OK TO INSTALL NEW SLAT. INSTALLED RT NR 1 SLAT TO STEP NR 1 ALL BOLTS REQUIRE TORQUE AND SECURE PERFORMED IAW MM 27-80-20-4. COMPLETED TO SUBTASK 27-80-20-865-012. AO T BOLTS TORQUED. INSTALLED RT NR 1 SLAT COMMON TRACK ECCENTRIC THRU STUD REF AMM 27-80-20-4 (REF LP 601589)