What was found
INSPECTION TYPE:N/A ENG NR 3 LOOP -A- FAULT, UP RT FIRE DET ASSY -A-. HARNESS 420581-0000 DISCONNECTED AT DETECTOR H4. FOUND BROKEN TERMINAL POD REQ A891931.1315245. REMOVED AND REPLACED HARNESS 420584-0000 REF MM 26-11-03 REF LOG PG 612163, ITEM 3. RE-ATTACHED MOUNT BOLTS ON DETECTOR. RTS CK PASSED THIS CLEARS D327547.