What was found
INSPECTION TYPE:C1 SUPPORT ANGLES CORRODED ON BOTH SIDES OF NR 7 MCD LATCH SPOOL FITTING. REMOVED, FABRICATED, AND INSTALLED REPAIR SUPPORT ANGLES ON NR 7 MCD LATCH SPOOL FITTING IAW DWG 4773295, AND SRM 51-3-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 SUPPORT ANGLES CORRODED ON BOTH SIDES OF NR 7 MCD LATCH SPOOL FITTING. REMOVED, FABRICATED, AND INSTALLED REPAIR SUPPORT ANGLES ON NR 7 MCD LATCH SPOOL FITTING IAW DWG 4773295, AND SRM 51-3-2.