What was found
INSPECTION TYPE:C LT HORIZ STAB NR 36 BARREL NUT HOLE FOUND CORRODED. CORROSION AT BARREL NUT BORE REMOVED PER SRM 51-21-01V.2R.35. BARREL NUT BORE BOTTOM MACHINE DOWN 0.050" DEEPER AND BORE REAM FURTHER TO2.586" DIA PER EN1697-07. B/NUT BORE BLEND OUT VOIDS AND BOTTOM PERIPHERY RADIUS SMOOTHEN AND PROTECTED PER SRM 1-21-01V.2R.35. REP SLEEVE BUSHING FAB AND PROTECTED PER EO MD11-5510-19409-L. REPAIR C/OUT IS ACCEPTABLE PER EN 1697-07.