What was found
INSPECTION TYPE:C LT HOR STAB NR 1 BARREL NUT HOLE FOUND CORRODED. CORROSION AT BARREL NUT BORE REMOVED PER SRM 51-21-01V.2R.35. 10X MAGNIFICATION DETAILED VISUAL INSP C/OUT AND FOUND NO CORROSION EVIDENT. BARREL NUT BORE BOTTOM AND BLEND OUT PERIPHERY RADIUS SMOOTHED AND PROTECTED PER SRM 51-21-01V.2R.35. REP SLEEVE BUSHING FAB AND PROTECTED PER EO MD11-5510-19409 -L FIG 5. REP C/OUT AT NR 1 LT BORE IS ACCEPTABLE PER EN179-07.