As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C CTR CARGO DOORWAY AREA STA 1745 TO STA 1764 FOUND SUPPORT FITTING WITH ELONGATED MOUNTING HOLES. 02EA DISCREPANT HOLES AT CTR CARGO DOORWAY REAMED TO 0.465" & 0.425" DIA RESPECTIVELY PER EN1721-07. HFEC INSP CUTOUT PER DAC NDTSPM R.13 06-10-0 1.003 FOUND NO CRACK EVIDENT. REP BUSHING USING MATL 7075-T6 & REP STRAP 01 USING MATL 7075T6-0.190" FABRICATED PER EN1721-07. 02EA BUSHINGS & 01EA REPAIR STRAP INSTALLED PER EN1721-07 ON SUPPORT FITTING.