What was found
INSPECTION TYPE:C2 FLOORBEAM AT BS 1200 BL 0 TO LBL 65 WL 208 IS CORRODED AT NUT PLATES. FLAP PEENED, ALODINED, PRIMED, APPLIED SEALANT IAW ATS ER 08-3101.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 FLOORBEAM AT BS 1200 BL 0 TO LBL 65 WL 208 IS CORRODED AT NUT PLATES. FLAP PEENED, ALODINED, PRIMED, APPLIED SEALANT IAW ATS ER 08-3101.