As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A PIT 32 DOOR CRACKED. ACCOMPLISHED HFEC INSPECTION PER EO DC8-5230-28827 PAR 6 A2. ACCOMPLISHED STOP DRILL PER EO DC8-5230-28827 PAR 6 A3-A4. NEEDS HFEC. ALSO REMOVED MOUNT BOLTS & 2 EA RIVETS FOR ACCESS. PERFORMED EDDY CURRENT ON STOP DRILL. NO CRACKS NOTED.