What was found
INSPECTION TYPE-C2 POSSIBLE CRACK IN RADIUS OF INTERCOSTAL ATTACH ANGLE, AT BOTTOM J-BEAM, AFT SIDE OF APB, 60 COMPT RT BS 1771. REMOVED INTERCOSTAL ATTACH ANGLE, FABRICATED AND INSTALLED REPLACEMENT ANGLE. IAW DWG 5773844 AND SRM 51-1-21,51-3-00 AND 51-1-20D.