What was found
PITS 32 AND 34 CARGO DOOR INNER CRACKS. ISSUED DEFERRAL D380080 IAW EO DC8-5230-29933-A. DAMAGE CONSISTS OF 2.0" LONG CRACK LOCATED ON THE INSIDE RADIUS OF FRAME. VERIFIED ENDS OF CRACK IAW NDT MANUAL 06-10-01 MARKED ENDS. MEASURED CRACK TO BE 2.0" LONG. STOP DRILLED CRACKS IAW EO DC8-5230-29933 STEP 6 (A) 4. AFTER STOP DRILL HFEC PERFORMED, NO CRACKS FOUND. DEFERRAL WAS FOR REPEAT INSPECTIONS.