What was found
INSPECTION TYPE:C LT WING NR 5 SLAT T/E WEDGE HAS 2 DENTS OUT OF LIMITS DUE TO PROXIMITY 69.0 INCHES FROM OTBD END, 1.6 INCH FROM T/E, 1.7 INCH DIA. REMOVED TOPCOAT TO PREP FOR BOND DOUBLER IAW SRM 57-43-02/51-70-10 REPAIR NR 2 E(C) PG 203 FIG 201. CLEANED/PREP AREA FOR BOND IAW SRM 57-43-02/51-70-10 REPAIR NR 2 E(C) PG 203, FIG 201. FABRICATED DOUBLER 2024T3, (BATCH NR 0001391211, PO NR MST00025129) IAW SRM 57-43-02/SRM 51-71-10, REPAIR NR 2, E(C) PG 203, FIG 201. PREP MATING SURF BOEGEL (BTCH NR 0001489157 PO NR MST0026211).