What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON THE HORIZONTAL STABILIZER RIGHT HAND INBOARD CLOSURE WEB, INSIDE ACCESS HOLE 9223 AREA, FWD WEB UPPER END WHERE THE WEB ATTACHING BRACKET IS MOUNTED AND EXTENDING 16 INCHES FWD. MAINTENANCE REMOVED, FABRICATED AND INSTALLED NEW CLOSURE WEB IAW SRM.