What was found
INSPECTION TYPE-C, RT AFT EMERGENCY EXIT HAS TWO OPEN HOLES AND ONE HOLE IS CRACKED OUT TO THE EDGE OF SKIN. CUT OUT DAMAGE ON RT AFT EXIT DOOR PER SRM 52-40-2 FIG 1, FAB'D DOUBLER AND INSTALLED IAW SRM 52-40-11, 52-40-2 FIG 1 AND SRM 51-30-2.