What was found
INSPECTION TYPE-C/CK, RIGHT CENTER WING STA XCW23 WEB HAS CRACKED LOWER ATTACH ANGLE AT ST RINGER 58. REMOVED CRACKED ATTACH ANGLE, LOCATED, DRILLED AND REAMED NEW ATTACHED ANGLE IAW DC8 SRM 51-1-24, ALODINED AND PRIMED NEW ATTACH ANGLE IAW DC8 SRM 51-1-8, INSTALLED NEW ATTACH ANGLE IAW DC8 SRM 51-1-20A.