What was found
INSPECTION TYPE-C, NR 2 TO NR 4 LEFT HAND LEADING EDGE SPAR ATTACHMENT HOLES HAVE CRACKS. REAMED HOLES 2 + 3 TO .500 REAMED HOLE 4 TO .747 NO CRACKS NOTED. FABRICATED AND INSTALLED BUSHINGS ANGLE DOUBLERS, FILLERS AND STRESS COI NED ALL HOLES IAW DAC DWG J060232 AND REO 02487 ANAD DPS 3.67-56