What was found
INSPECTION TYPE-C, NR 2 TO 5 HOLES HAVE CRACKS ON RT L/E SPAR ATTACHMENT HOLE INB OF NR 4 PYLON REAMED HOLES 2, 4, 5 TO .500 AND NR 3 HOLE TO .747, NO CRACKS NOTED. FABRICATED AND INSTALLED BUSHINGS, STRAPS, FILLERS AND ANGLES IAW DAC DW G J06032 AND DC8 SRM 51-9-0 AND REO 02493.