What was found
INSPECTION TYPE-SI, WHILE WORKIING TC NR 53-111-01-3C FOUND CRACKED INTERCOSTAL BS 1110 TO 1130, STR 25R AND MISSING FASTENERS AT BS 1110. REMOVED AND REPLACED INTERCOSTAL FROM BS 1110 TO 1130 STR 25R PER SRM 51-10-2, 51-30-2, 51-20-1.