What was found
INSPECTION TYPE-SI, CORROSION ON INTERCOSTAL AT BS 294.5-312 RBL 30 WL 207. CORROSION REMOVED WAS OUT OF LIMITS. REMOVED INTERCOSTAL, FABRICATED ANOTHER INTERCOSTAL, INSTALLED ALL WORK DONE IAW SRM 51-30-2, 53-10-1, 51-20-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-SI, CORROSION ON INTERCOSTAL AT BS 294.5-312 RBL 30 WL 207. CORROSION REMOVED WAS OUT OF LIMITS. REMOVED INTERCOSTAL, FABRICATED ANOTHER INTERCOSTAL, INSTALLED ALL WORK DONE IAW SRM 51-30-2, 53-10-1, 51-20-05.