As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE-C, NR 4 K-FLAP O/B BONDING JUMPER HOLE HAS CORROSION AROUND OLD BONDING JUMPER LOCATION. CORROSION REWORK OUT OF LIMITS IAW UPS EO B727-5740-3980 (SRM ADDENDOM) REPAIRED NR 4 K-FLAP AT OLD BONDING JUMPER LOCATION IAW SRM 57-50-3.