What was found
INSPECTION TYPE-C, BS 2120 TO BS 2140 STR 28 LT WEB BETWEEN FLOORBEAMS ADJACENT FOUND TO BE CRACKED. CRACKED WEB OUT OF LIMITS ACC SRM 53-10-01 AT BS 2120 TO BS 2140 STR 28 LT. REPLACED WEB ACC SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, BS 2120 TO BS 2140 STR 28 LT WEB BETWEEN FLOORBEAMS ADJACENT FOUND TO BE CRACKED. CRACKED WEB OUT OF LIMITS ACC SRM 53-10-01 AT BS 2120 TO BS 2140 STR 28 LT. REPLACED WEB ACC SRM 51-30-02.