What was found
INSPECTION TYPE-N/A ON TAKEOFF CALLED FOR GEAR UP HANDLE WOULD NOT MOVE AT SAME TIME MAIN GEAR SPOILER INOP CAME ON, COMPLETED MAIN SPOILER INOP CHKLST LIGHT WENT OUT, ELECTED NOT TO RAISE GEAR. DUE TO NOISE PREVIOUSLY NOTED. *S/D* PERFORMED ADJ AND TEST OF LANDING GEAR MECHANICAL CONTROL SYS PER MM 32-31-00, FOUND PUSH RODS ON NOSE GEAR CONTROL U/U OUT OF ADJ PUSH RODS AND OPS CHK SYS, CHKS GOOD. ALSO, PERFORMED VISUAL INSP FOUND NO DEFECTS IN NLG AREA. PERFORMED GEAR SWING ALL SYS CHK GOOD 32-31-00.