What was found
INSPECTION TYPE-C/CK, FWD SERVICE DOOR DOOR JAM WEBBING AFT END HAS 3 CRACKED PLACES AT FUSELAGE STATION 200 BETWEEN LONGERON 13 RT AND 14, AND RT 17. REMOVED WEB AND FABRICATED IAW DAC DRAWING 5615700, ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED IAW DC8 SRM 51-1-21 AND 51-1-20D.