What was found
INSPECTION TYPE:D ON ACCOMPLISHMENT OF EDDY CURRENT INSPECTION OF RT E-F WINDOW POST PER EO B727-5310-0012, CRACKS FOUND ON 3 HOLES COMMON TO REPAIR STRAP. REPAIR CARRIED OUT IAW SRS ENGINEERING ORDER 98-24-012, REF UPS ENGINEERING FILE NUMBER 727-5310-2066.