What was found
INSPECTION TYPE-C, C PIT FLOOR TRACK SUPPORT HAS CORROSION UNDER NUT PLATES FROM FS 980 TO 1200 LONG 33L. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT TRACK SUPPORT IAW SRM 51-1-21 AND DWG 5751516.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, C PIT FLOOR TRACK SUPPORT HAS CORROSION UNDER NUT PLATES FROM FS 980 TO 1200 LONG 33L. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT TRACK SUPPORT IAW SRM 51-1-21 AND DWG 5751516.