What was found
INSPECTION TYPE:C+S2 FS 450 LONG 31R CORRODED AND CHIPPED METAL ALONNG EDGES AND FASTENER HOLES AT THE FWD END OF FITTING. REMOVED FASTENERS IAW DC8 SRM 51-1-20D. REMOVED CORROSION IAW WITH DC 8 SRM 51-1-8. FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0. BLENDED DAMAGE IAW DC8 SRM 53-2-0 DRILLED NEW FITTING IAW DC8 SRM 51-3-2. INSTALLED FITTING IAW DC8 SRM 51-1-20D.