What was found
PILOT REPORT, SMOKE IN FLT DECK ON LANDING. WITH EQUIP COOLING MSG OVERHEAT LIGHT ILLUMINATED EICAS MSG CLG FAN DISPLAYED. OVHT LGT EXT IN WHEN ALT WAS SELECTED. RESET 3 PHASE FWD COOLING FAN 1 ON P6. RAN FAN ON GROUND 1.5 HRS, OPS NORMAL, NO HISTORY.