What was found
INSPECTION TYPE:C123, FS 680, BL 0, THE FLOORBEAM TO BULKHEAD ATTACH FITTING IS CRACKED. REMOVED, FABRICATED AND REPLACED THE FITTING IAW DWG 5773275 AND SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C123, FS 680, BL 0, THE FLOORBEAM TO BULKHEAD ATTACH FITTING IS CRACKED. REMOVED, FABRICATED AND REPLACED THE FITTING IAW DWG 5773275 AND SRM 51-1-20D.