What was found
PIT - FOUND SKIN CRACKED .15625 CRACK AND SMALL DENT, 6 INCHES FORWARD OF MED DOOR FRAME BETWEEN DOOR HINGES. DOUBLER INSTALLED PER SRM 53-10-01 FIG 205 AND EA 73704. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND SKIN CRACKED .15625 CRACK AND SMALL DENT, 6 INCHES FORWARD OF MED DOOR FRAME BETWEEN DOOR HINGES. DOUBLER INSTALLED PER SRM 53-10-01 FIG 205 AND EA 73704. (M)