What was found
CLT - FOUND WEB CRACKED .200 INCH, UPPER HINGE CUTOUT WEB L4 DOOR. FABRICATED DOUBLER, TRIMMED OUT DAMAGE, INSTALLED REPAIR PER EA 87189. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND WEB CRACKED .200 INCH, UPPER HINGE CUTOUT WEB L4 DOOR. FABRICATED DOUBLER, TRIMMED OUT DAMAGE, INSTALLED REPAIR PER EA 87189. (M)