What was found
BFM - FOUND BEAM CORRODED 2.8 IN BY 1.2 INCH BY .050 INCH DEEP AREA, FRAME 16, -Y1292, -Z240. CORROSION LEVEL 2, TASK NR JA-220-53500. FABRICATED AND INSTALLED ANGLE, DOUBLER, FILLER PER SRM 53-11-14, 53-1-14, 51-42-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND BEAM CORRODED 2.8 IN BY 1.2 INCH BY .050 INCH DEEP AREA, FRAME 16, -Y1292, -Z240. CORROSION LEVEL 2, TASK NR JA-220-53500. FABRICATED AND INSTALLED ANGLE, DOUBLER, FILLER PER SRM 53-11-14, 53-1-14, 51-42-11. (M)