What was found
LEFT AFT ENTRY DOOR THRESHOLD CORRODED .75 X 3 X .070 INCH DEEP AT UPPER SPLICE ANGLE STATION FR 67. NO CORROSION LEVEL OR TASK. REMOVED UPPER SPLICE ANGLE, FABRICATED AND INSTALLED REPAIR ANGLES PER SRM 53-41-14, REPAIR PRINCIPAL 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT AFT ENTRY DOOR THRESHOLD CORRODED .75 X 3 X .070 INCH DEEP AT UPPER SPLICE ANGLE STATION FR 67. NO CORROSION LEVEL OR TASK. REMOVED UPPER SPLICE ANGLE, FABRICATED AND INSTALLED REPAIR ANGLES PER SRM 53-41-14, REPAIR PRINCIPAL 2.