What was found
PIT - S1 - MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON FLOOR BEAM BETWEEN FR12 TO FR24, S23R, -Y1292. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, S23R, -Y1292 IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S1 - MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON FLOOR BEAM BETWEEN FR12 TO FR24, S23R, -Y1292. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, S23R, -Y1292 IAW A319 SRM 51-72-11.