What was found
PIT - S1 - MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON DOOR SILL BEAM AT FR66, Y1732. REPAIRED DOOR SILL BEAM AT FR66, Y1732 IAW A319 SRM 53-41-14 REPAIR 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S1 - MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON DOOR SILL BEAM AT FR66, Y1732. REPAIRED DOOR SILL BEAM AT FR66, Y1732 IAW A319 SRM 53-41-14 REPAIR 6.