Service difficulty report · Sense Line · Emb ERJ190100IGW

Difficulty date
July 23, 2011
Submitted
July 25, 2011
Operation
Air carrier
Aircraft
N952UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000119
Aircraft time
8,356 hours, 7,003 cycles
Part
Sense Line
Part number
10023911
Part serial
D06100860
Condition
Contaminated
Location
Bleed Air Sys
Part time
8,363 hours, 7,009 cycles
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 703, PHL-PIT - BLEED 2 OVERPRESS CAUTION EICAS ON CLIMBOUT. QRH PROCEDURE FOLLOWED. BLEED 2 OVERPRESS REMOVED ANNUNCIATED UNTIL NR 2 THRUST LEVER TO IDLE IAW QRH. NOTE: ON ECS SYNOPTIC PAGE. NR 2 BLEED INDICATED 120 PSI BEFORE BLEED SELECTED OFF. MAINTENANCE - PER FIM PROCEDURE 36-14-00-810-809A, REMOVED WATER CONTAMINATION FROM PRESSURE SENSE LINE, AND REMOVED AND REPLACED BLEED PRESSURE SENSOR PER AMM 36-14-02 UPS CHECK GOOD AT THIS TIME.

More about the Emb ERJ 190-100 IGW