What was found
C11 CHECK, LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69 & BETWEEN FR69 & FR70, Y160.5. REPLACED FLOORBEAM IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK, LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69 & BETWEEN FR69 & FR70, Y160.5. REPLACED FLOORBEAM IAW SRM 51-42-11.