What was found
C11 CHECK, LEVEL 2 EXFOLIATION CORROSION ON L2 DOOR SHAPE SILL AT FR67, S23L, Z-500, Y1732. REPLACED L2 DOOR SILL IAW SRM 51-44-11, 51-21-11 & DRAWING D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK, LEVEL 2 EXFOLIATION CORROSION ON L2 DOOR SHAPE SILL AT FR67, S23L, Z-500, Y1732. REPLACED L2 DOOR SILL IAW SRM 51-44-11, 51-21-11 & DRAWING D53480505.