What was found
C11 SYS 6 CHECK LEVEL 2 EXFOLIATION CORROSION ON R2 DOOR SILL BETWEEN FRAME 66 TO FRAME 68, Z 500 & Y 1589. REPLACED R2 DOOR SILL BETWEEN FRAME 66 TO FRAME 68, Z 500 & Y 1589 IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 SYS 6 CHECK LEVEL 2 EXFOLIATION CORROSION ON R2 DOOR SILL BETWEEN FRAME 66 TO FRAME 68, Z 500 & Y 1589. REPLACED R2 DOOR SILL BETWEEN FRAME 66 TO FRAME 68, Z 500 & Y 1589 IAW SRM 51-72-11.