A SMOKE DETECTOR FAULT DISPLAYED ON ECAM. REPLACED LAVATORY E SMOKE DETECTOR FILTER. LAVATORY SMOKE DETECTION SYS OPERATIONS TESTED NORMAL IAW AMM TASK 26-17-00-710-001.